Machine safety · AS/NZS 4024
Machine safety assessment, design and validation to AS/NZS 4024.
Services
The whole safety lifecycle, or the part you're stuck on.
Risk assessment
Hazard identification, risk estimation and the hierarchy of control, following ISO 12100 as adopted in the AS/NZS 4024.1 series. On new machinery and on the plant you already run.
Safety requirements specification
A safety functions list with a required performance level for each, plus reaction times, stopping distances, reset behaviour and what happens on loss of power, air or signal.
Design and PL verification
Architecture category, MTTFd, diagnostic coverage and common-cause failure worked through for every function and calculated to ISO 13849-1. IEC 62061 where SIL is the better fit.
Safety PLC and relay implementation
Safety logic written, reviewed and kept separate from standard control. E-stops, guard interlocks, light curtains, two-hand controls, muting and safe speed.
Validation
Validation to ISO 13849-2: analysis plus fault-injection testing of each safety function on the real machine, recorded so it stands up to scrutiny later.
Gap assessments and upgrades
Existing and imported machinery assessed against current practice, with a prioritised, costed path to close the gaps without rebuilding everything.
Interactive
How much safety does a function need?
ISO 13849-1 sets the required performance level from three questions: how badly someone could be hurt, how often they're exposed, and whether they could get out of the way. Try a hazard on your own machine.
Then comes the real work: designing a circuit that meets the PLr, proving it by calculation, and proving it again by test.
Required performance level
PLe
S2 · F2 · P2
Indicative only. A real PLr comes out of a documented risk assessment, which also considers stopping performance, the people exposed and how the machine is actually used.
What you get
Documents that survive an incident investigation.
If something goes wrong, the question is what you knew and what you did about it. Every engagement ends with records that answer it.
- 01Risk assessment and hazard register
- 02Safety functions list and SRS
- 03PL calculations per function
- 04Safety circuit and PLC design review
- 05Validation plan and test records
- 06Validation report and sign-off pack
Standards we work to
- AS/NZS 4024.1 series
- ISO 12100: risk assessment
- ISO 13849-1 / -2: design and validation
- IEC 62061: functional safety (SIL)
- IEC 60204-1: electrical equipment
- ISO 13850: emergency stop
- ISO 14119: interlocking devices
- ISO 13855: positioning of safeguards
- IEC 62745: cableless control
Questions
Is AS/NZS 4024 mandatory?
Our machine came from overseas with a CE mark. Is that enough?
Can you work with our existing safety PLC or relays?
Do you do the electrical installation?
Can you help with wireless or cableless safety?
Not sure where your machine stands?
Start with a walk-through. We'll tell you what's sound, what isn't, and what to fix first.